Gate ~ FMCU Galaxy Gate ~ User Guide

De.png En-active.png




Introduction

The document describes the functions and configuration options of the software Facility Management Control Unit.

The Facility Management Control Unit is software for access control management. It can be used in an enclosed area such as a sports or entertainment center, an airport zone, universities or security areas. The main components of the software solution are:

  • An automated passage control with two-part door and signal lighting
  • Barcode (or/and RFID) scanners that read identification data from the customer's ticket or card
  • Tracking cameras observing the passage of customers
  • Info screens showing inbound and outbound information to the customer
  • One or more external speakers
  • One or more additional monitors with content tailored to customer needs

The main features are:

  • Opening access control upon successful ticket validation
  • Interaction with customer in response to various events through:
    • Light effects
    • Voice prompts through internal or external speakers
    • Acoustic confirmation of the reading process from barcode scanners
    • Visual content displayed on an info screen
    • Safe opening and closing of the swing doors by monitoring the passage area

Supported operating modes:

  • Normal
  • Service
  • Fire alarm
  • Emergency

The variants of Entry Tickets:

  • Single entry ticket with closing of access control after passage of one person
  • Multiple entry ticket with permanent access control
  • Adjustable time intervals
  • Consideration of additional conditions about potential-free contacts

Technical Information

Configuration

Step 1

After the software has been downloaded and transferred to the eMMC card according to the documented procedure, see also here Galaxy Gate Inbetriebnahme, the login screen appears after the first start. After logging in with the user Installer, the wizard with the definition of the IP configuration is started.

image network assistant.png
Parameter Description Default Value
Address IP-Address of access control 192.168.1.100
Mask Network-Mask 255.255.255.0
Gateway Gateway-Address 192.168.1.1
DNS-Server DNS-Server for name resolution 192.168.1.1
Maxcrc MediaWiki:Icon-info.png
Note
The configuration always starts with the "Slave" side of the Galaxy Gate. This selection is preset in the assistant "No Device Slave".

As a type, you can basically make this selection in the assistant.

Configuration of the Facility Management Control Unit
Selection Description
No Device Slave Slave Unit (Default Selection)
Galaxy Gate (Modbus Serial) Master-Unit mit serieller Verbindung zu Slave-Unit
Galaxy Gate (Modbus TCP) Master-Unit with network connection to Slave-Unit
Galaxy Port (Modbus Serial) Unit with serial connection to Slave-Unit
Galaxy Port (Modbus TCP) Unit with network connection to Slave-Unit
Functions
Function Description
AEA Configuration for Boarding Gates
Immediate Closure Closing the swivel arms without swivel range monitoring
Multiple Opening Swivel arms remain open when multiple input signals are present
Personal Protection Closing the swivel arms with swivel area monitoring
One-time opening Single pass even when several input signals are present
Trolley Case Support of trolley case without alarm
Wheelchair Assistance from wheelchair without alarm

After the function has been selected, the combination of functions results in corresponding configuration types. The function selection is a filter for the resulting configuration type.

Configuration type from combination of functions
Configuration Type Description
AEA Configuration for Boarding Gates
One-time opening Personal Protection Closing the swivel arms with swivel area monitoring
One-time opening Immediate Closure Closing the swivel arms without swivel range monitoring
One-time opening Trolley Case Single passage with trolley case even when several input signals are present
One-time opening Wheelchair Single passage with a wheelchair even if several input signals are present
Multiple opening personal protection Closing the swivel arms with swivel area monitoring
Multiple opening instant closure Closing the swivel arms with swivel area monitoring
Multi-opening trolley case Swivel arms remain open when several people with wheeled suitcases pass through
Multiple opening wheelchair Swivel arms remain open when several people with wheeled suitcases pass through

After choosing from the three lists, click on Apply, the application will be restarted, you have to wait for the start-up process to be completed. After logging in again, this screen appears.

Maxcrc MediaWiki:Icon-info.png
Note
If you adjust the IP address in the configuration, you must also align the URL in the browser to the new IP address.
image assistant step02.png

After the input fields have been filled in, you can click on Next to reach the next page of the wizard.

image assistant step03.png

The current WEAC firmware is displayed on the next page of the wizard. If necessary, you can down or upgrade the firmware.

image assistant step04.png

The firmware version for each unit is listed as a label next to the activation button. The navigation options are deactivated during the update process. The update process takes about 3 minutes for both units.

image assistant 04a.png

After checking the WEAC firmware, the swing doors are configured. It is automatically checked whether the minimum requirements regarding the firmware are met. You will be informed on the surface if the firmware has to be updated first.

image assistant 05.png

If the requirements are met, you can select the swing doors and apply them to the gate.

image assistant step06.png

The next step is to configure the LED player for both units (Master and Slave) accomplished. If necessary, you can adjust the parameters. If the status is ready for use, no modifications are necessary.

image assistant step07.png

The current firmware of the LED player is shown again on the last page of the assistant. Optionally, you can end the configuration with a restart. However, this is only necessary if IP addresses or interface information have changed.

image assistant Step08.png

After clicking Finish, you can now log in again with a known credentials and work with the Galaxy Gate. If you log in again with the user installer, you get a graphical overview, can find out about the status of the access control and can carry out updates if necessary. This completes the setup of the access control.

image status.png

You can now log in with a service account and carry out further tests.

Operation Manual

Configuration of the Swing Doors

The swing doors can have different dimensions. Depending on the width and height, this results in other target parameters for optimal curve passage.

image glasdoors.png

After a type has been selected, all parameters can be adjusted according to the needs in the interface before they are then activated via the button Apply in the configuration on the access control. If you change individual values in the display, the settings must first be saved. To do this, click on the diskette symbol on the left of the interface above the file list.

image door settings.png

After the changes have been saved, you can activate them using the Apply button.

Configuration of the XOVIS Sensors

Add XOVIS-Sensor

Navigate to "Configuration" -> "Devices" -> "Xovis Cameras" and then click on the "Add" button

add xovis device 1.png

The following fields are filled in the order shown:

  1. Name
  2. URL
  3. Username
  4. Password
add xovis device 2.png

The configuration is saved by clicking the Save button.

Maxcrc MediaWiki:Icon-info.png
Note
After adding the XOVIS sensor, the FMCU must be restarted before proceeding with the configuration.

Add XOVIS monitoring area as alarm signal

Navigate to "Configuration" -> "Signals" and then click on the "Add" button

add xovis alarm signal 1.png

The following fields must be filled in here:

  1. Select type "XOVIS Sensor"
  2. Specify the name of the signal (e.g. "XOVIS ALARM")
  3. Set the minimum number of people in the alarm zone to trigger an alarm (e.g. 2)
  4. Select the alert type (e.g. "Unauthorized Access")
  5. Determine a list of alarm zones (e.g. "AlarmZone")
  6. Select the XOVIS sensor added to.

The configuration is saved by clicking the Save button.

add xovis alarm signal 2.png

Add XOVIS counter Navigate to "Configuration" -> "Signals" and then click on the "Add" button

add xovis alarm signal 1.png

The following fields must be filled in here:

  1. Select type "XOVIS Sensor".
  2. Specify the name of the signal (e.g. "XOVIS Counter")
  3. Specify the side of the gate (e.g. "Entrance")
  4. Set the value "Counter".
  5. Specify a list of lines(e.g. "EntryLine")
  6. Select the XOVIS camera that you added earlier.

The configuration is saved by clicking the Save button.

add xovis counter signal.png

Store VPN key

A VPN key is required to use remote maintenance. This key can be requested from maxcrc support (support@maxcrc.de) by specifying the project name (Configuration->General view).

After the key file (*.opvn.conf) is available, you can import via the System->OpenVPN page. The following steps are necessary for this.

Navigating to the System-OpenVPN page.

image openvpn step01.png
image openvpn step02.png

This file is now specified via the Select file button in the file selection dialog. Then click on Upload. When the process has been successfully completed, an info icon will appear next to the start button. This means the file has been uploaded successfully, the OpenVPN client can now be activated by clicking on Start.

image openvpn step03.png

If the start was successful, the color changes from green to red and the label from start to stop. The status of the OpenVPN client and the IP address for access in the VPN network for this gate are displayed to the right of the info symbol. You can disable remote access by clicking the Stop button.

Softwareupdates

If there is no Internet connection, individual package installations can be carried out in the System->Update software menu. To do this, you create a zip archive with the packages to be installed beforehand. It must be ensured that no relative paths are used in the archive. Then you can insert the archive into the input line via Select file and start the update procedure with Upload. The progress process is displayed in the interface.

Display during installation
Anzeige nach Abschluss der Installation

If necessary, the application can be restarted.

Customer Role

When you log in with the user client, a simplified interface appears with only three configuration menus "Home", "Status", "Statistics".

image customer view.png

In this view you can administrate the access control, but you cannot make any configuration adjustments. The current statistics are displayed directly on the interface, a complete overview of the accesses can be viewed in the Statistics tab and exported if required. The current status of the individual access control components can be viewed in the Status tab. The Cleaning option disables all alarms to make the cleaning staff's job easier. The Emergency open option supports the user in opening the access control immediately.

Standard assignment connection board

Unit 1

Port Function Description
LSU (E1) LS Middle

Center Light barrier

NO

Normally Open Contact

LSV (E2) LS Entry

Photocell Input

NO

normally open contact

E3 Open Entry

Single free entry direction Impuls 0,1-1,0 Sek.

NO

Normally Open Contact

E4 Open Exit

Single free exit direction Impuls 0,1-1,0 Sek.

NO

normally open contact

LSH (E5) NA

not connected

E6 State bit 0

Status bit 0

NO

normally open contact

E7 State bit 1

Status bit 1

NO

normally open contact

E8 Fire Alarm

fire alarm system (BMA)

NC

normally closed contact

E9 Open Entry 70%

Einzelfrei 70% Input Direction Impuls 0,1-1,0 Sek.

NO

normally open contact

E10 Emergency Open Button

emergency button

NC

normally closed contact

A8 Entry Confirmation

Confirmation of passage entry direction Impuls 0,5 Sek.

+12 VDC
A9 Exit Confirmation

Confirmation of passage exit direction Impuls 0,5 Sek.

+12 VDC

Unit 2

Port Function Description
LSU (E1) NA

not connected

LSV (E2) NA

not connected

E3 Open Entry

Single free entry direction Impuls 0,1-1,0 Sek.

NO

normally open contact

E4 Open Exit

Single free exit direction Impuls 0,1-1,0 Sek.

NO

normally open contact

LSH (E5) LS Exit

Photocell exit

NO

normally open contact

E6 State bit 2

Status bit 2

NO

normally open contact

E7 State bit 3

status bit 3

NO

normally open contact

E8 Fire Alarm

fire alarm system (BMA)

NC

normally closed contact

E9 Open Exit 70%

single free 70% exit direction Impuls 0,1-1,0 Sek.

NO

normally open contact

E10 Emergency Open Button

emergency button

NC

normally closed contact

A8 Alarm Impuls

Alarm Impuls 0,5 Sek.

+12 VDC
A9 Gate State Error

error condition Durchgang

+12 VDC

Status Zustandsbits

Status Unit 1 E6

Bit 0

Unit 1 E7

Bit 1

Unit 2 E6

Bit 2

Unit 2 E7

Bit 3

Normal

Normal

0 0 0 0
Free Entry

Entrance permanently free

1 0 0 0
Lock Entry

entrance blocked

0 1 0 0
Service Entry

Permanently open entry direction

1 1 0 0
Free Exit

Exit permanently free

0 0 1 0
Free Entry/Exit

Input/Output permanently free(Not implemented)

1 0 1 0
Lock Entry / Free Exit

Entrance blocked / exit permanently free

0 1 1 0
tbd 1 1 1 0
Lock Exit

exit blocked

0 0 0 1
Free Entry / Lock Exit

Entrance permanently free / exit blocked

1 0 0 1
Lock

Gesperrt

0 1 0 1
tbd 1 1 0 1
Service Exit

Permanently open exit direction

0 0 1 1
tbd 1 0 1 1
tbd 0 1 1 1
Self Test

self test

1 1 1 1

Alarmdefinition

An alarm is triggered as a follow-up action from signals or other sources (e.g. devices). An alarm exists has several general characteristics. This includes a name, the definition of an action...

Definition Description Status
Connection Alive monitors connection to external application on/off
Connection Lost monitors connection to external application on/off
Counter Pass is set by anti-rotation protection is activated on/off
Door Break-In Door is forcibly moved when closed on/off
Emergency is set if the signals on unit 1 E8 or unit 2 E8 are not active (opener). on/off
Fire Alarm is set if the signals on unit 1 E10 or unit 2 E10 are not active (opener). on/off
Invalid Ticket is set if ticket validation fails Impuls
Motionless Object is set when an object is in the gate area for more than a defined period of time and closing is prevented by a timeout. on/off
No Alarm is set if no alarm is defined for signals on/off
Proceed Alarm analogous to Motionless Object with a different time span and other actions without light indication on/off
Server Alarm is triggered in the FMCU server on/off
Tailgating is set if more than one person is in the gate area on/off
Unauthorized Access is set if a person is in the gate area when the gate is closed on/off
Valid Ticket is set if the ticket validation was successful (trigger beep) Impuls

Signale

Die Informationen in diesem Abschnitt basieren auf der FMCU-Software v2.3.7 und der WEAC-Version 32.14.

FMCU-Signale.png

Technischer Hintergrund

Die Software FMCU basiert auf einem angepassten UNIX-Betriebssystem, welche unter Anwendung des Yocto-Projektes produziert worden ist. Es werden nur die benötigten Dienste im Betriebssystem aktiviert. Es werden die für den CPU-Typ optimalen Unterstützungspakete bei der Erstellung des Betriebssystems berücksichtigt. Diese sogenannten Board Support Packages (BSP) werden von den Hardwareherstellern zur Verfügung gestellt und gestatten eine optimale und effiziente Ausnutzung der Hardwareressourcen.

Funktionen

Grundsätzlich werden die Funktionen über die Signalverabeitung abgebildet. Die Signale werden durchunterschiedliche Quellen erzeugt. Dazu gehören:

  • Lichtleiste
  • Lichtsensor
  • Deckensensor
  • Sonstige

Die Anordnung der Sensoren ist in der nachfolgenden Abbildung dargestellt. In jeder Rahmenhälfte befindet sich eine sogenannte "Inner-Zone" und eine "Outer-Zone". Bei Durchschreiten einer Zutrittskontrolle wird ein Signalflussdiagramm erzeugt, welches für die Abbildung der nachfolgenden Funktionen genutzt wird.

image sensors.png

Die Lichtleiste dienst als Quelle für mehrere Signale und ist ebenfalls in unterschiedliche Bereiche unterteilt.

image lightbar.png

In der Standardkonfiguration sind folgende Signale konfiguriert.

Signalname Rahmenhälfte
Entry Confirmation Eingang
Entry Gate Sensor [U1_E2] Eingang
Entry Outer LightBar Eingang
Exit Inner LightBar Eingang
Free Entry [1000] Eingang
Lock Entry [0100] Eingang
Open Entry [U1_U2_E3] Eingang
Open Entry 70% [U1_E9] Eingang
Remote Open Entry Eingang
Service Entry [1100] Eingang
Emergency Remote Ausgang
Emergency [U1_U2_E8] Ausgang
Entry Inner LightBar Ausgang
Exit Confirmation Ausgang
Exit Gate Sensor [U2_E5] Ausgang
Exit Outer LightBar Ausgang
Free Exit [0010] Ausgang
Lock Exit [0001] Ausgang
Open Exit [U1_U2_E4] Ausgang
Open Exit 70% [U2_E9] Ausgang
Remote Open Exit Ausgang
Service Exit [0011] Ausgang

Schliessfahrt mit reduzierter Geschwindigkeit

Diese Funktion ist für Signale zutreffend, die die Eigenschaft CloseGate > 0 aufweisen. Bei den betroffenen Signalen muss der Wert Close gate speed, % * mit einem Wert zwischen 10 und 100% definiert werden. Es besteht somit die Möglichkeit, für unterschiedliche Durchgangszenarien entsprechende Schließgeschwindigkeiten zu definieren. Der Standardwert ist auf 100% festgelegt. In der Standardkonfiguration erfüllen folgende Signale diese Voraussetzung.

Signal Parameter Wert
Tailgating watcher Close gate speed, % * 100%
Entry Gate Sensor [U1_E2] Close gate speed, % * 100%
Exit Gate Sensor [U2_E5] Close gate speed, % * 100%
Entry Outer LightBar Close gate speed, % * 100%
Exit Outer LightBar Exit Close gate speed, % * 100%

Durchgangsbestätigung

Diese Funktion setzt einen Impuls mit einer einstellbaren Zeitdauer im Anschlussboard für den Anschluss A8.Zusätzlich wird erfolgte Durchgang in der Statistik berücksichtigt.

Koffertrolleyerkennung

Diese Funktion ist aktiv wenn bei folgenden Signalen die aufgeführten Parameter gesetzt werden. Es bedeutet, dass eine Personen mit einem hinter sich herziehenden Koffer ohne Störung durch vorzeitig schleißende Schwenktüren passieren kann.

Signal Parameter Wert
Middle Gate Sensor [U1_E1] Protect from force close true
Inner LightBar Protect from force close true

Mehrfachöffnung

Diese Funktion ist nur dann gültig, wenn ein Leser für die Eingangsrichtung eingerichtet worden ist. Es bedeutet, dass mehrere Personen in einer Reihe nacheinander den Eingang passieren können, ohne dass die Schwenktür zwischenzeitlich geschlossen wird. Es muss von jeder Person ein Ticket am Kartenleser am Eingang präsentiert werden. Nur bei erfolgreicher Validierung bleiben die Schwenktüren geöffnet. Diese Funktion ist aktiv wenn bei folgenden Signalen die aufgeführten Parameter gesetzt werden.

Signal Parameter Wert
Middle Gate Sensor [U1_E1] Protect from force close true
Inner LightBar Protect from force close true
Entry Outer LightBar Protect from force close true
Entry Gate Sensor [U1_E2] Protect from force close true
Tailgating watcher Aktiviert false

Tipps zum Arbeiten

image reset-to default.png

Wenn man die Übersicht bei der Konfiguration der Signale verloren hat, kann man über die Funktion

Reset to Default

einen definierten Ausgangszustand wiederherstellen.

Maxcrc MediaWiki:Icon-info.png
Hinweis
Wenn man die Funktion "Rest to Default" anwendet, gehen die aktuellen Einstellungen verloren. Man kann bei Bedarf vor diesem Schritt die aktuelle Konfiguration exportieren.