Connectivity Board


Contact Modbus Value/Flag Type Impulse Description
A8 0x47 Output Yes (200ms) Person has entered
A9 0x48 Output No Alarms*
E3 0x004 Input No Fire Alarm
E4 0x008 Input No Emergency State button**
E6 0x020 Input Yes (200ms) Card is valid, open the gate
E7 0x040 Input Yes (200ms) Card is invalid, do not open the gate  

*A9 Alarms:

  • Gate is out of order, when a mandatory device is broken or a connection to the server is broken (if the server is used in the solution).
  • Tailgating or other unwanted actions.
  • Entry barcode scanner is broken or it is a stub.
  • Gate in in the Fire Alarm or Emergency state. The alarm is produces as a repetitive pulse signal (700ms).
  • Gate is open only for exit.

After the Emergency State button pressed, the gate switches to the Emergency State. Then only exit from this state is to restart the gate.

The signal can be set/received to/from a contact from any of the halves of the gate.

Configuration Management


User Interface

The Galaxy Gate is configured through the /configuration page. If the server is running at 192.168.1.221 and port is 8888, the url is:

http://192.168.1.221/configuration
configuration page


There are two buttons on the page:

Name Description Action
Save Saves the modified configuration to the server Post
Reset Discards any changes by reloading the configuration from the server Get

The configuration is split into sections and subsections:

  • General
    • Dispatcher
    • Miscellaneous
  • Devices
    • Barcode Reader Entry
    • Barcode Reader Exit
    • Gate
    • Tracking Camera
    • Audio Player
    • Camera
  • Displays
    • Display Gate Entry
    • Display Gate Exit
    • Display Entry
    • Display Exit
    • Display TimeInfo
gg-barcode-reader-gate.png