en
< Gate ~ FMCU ~ management dashboard
Version vom 5. Dezember 2019, 23:24 Uhr von Rehlert (Diskussion | Beiträge)
Connectivity Board
Contact | Modbus Value/Flag | Type | Impulse | Description |
---|---|---|---|---|
A8 | 0x47 | Output | Yes (200ms) | Person has entered |
A9 | 0x48 | Output | No | Alarms* |
E3 | 0x004 | Input | No | Fire Alarm |
E4 | 0x008 | Input | No | Emergency State button** |
E6 | 0x020 | Input | Yes (200ms) | Card is valid, open the gate |
E7 | 0x040 | Input | Yes (200ms) | Card is invalid, do not open the gate |
*A9 Alarms:
- Gate is out of order, when a mandatory device is broken or a connection to the server is broken (if the server is used in the solution).
- Tailgating or other unwanted actions.
- Entry barcode scanner is broken or it is a stub.
- Gate in in the Fire Alarm or Emergency state. The alarm is produces as a repetitive pulse signal (700ms).
- Gate is open only for exit.
After the Emergency State button pressed, the gate switches to the Emergency State. Then only exit from this state is to restart the gate.
The signal can be set/received to/from a contact from any of the halves of the gate.
Configuration Management
User Interface
The Galaxy Gate is configured through the /configuration page. If the server is running at 192.168.1.221 and port is 8888, the url is:
http://192.168.1.221/configuration
There are two buttons on the page:
Name | Description | Action |
---|---|---|
Save | Saves the modified configuration to the server | Post |
Reset | Discards any changes by reloading the configuration from the server | Get |
The configuration is split into sections and subsections:
- General
- Dispatcher
- Miscellaneous
- Devices
- Barcode Reader Entry
- Barcode Reader Exit
- Gate
- Tracking Camera
- Audio Player
- Camera
- Displays
- Display Gate Entry
- Display Gate Exit
- Display Entry
- Display Exit
- Display TimeInfo
Here are some screenshots: