Gate ~ FMCU Galaxy Gate ~ management dashboard

De.png En-active.png



General

The Wanzl Access Manager offers a central dashbaord for access controls in a homogeneous interface, displays the corresponding states and supports the user in the administration of these components. The Wanzl Access Manager is a leading platform for monitoring and managing access controls of security areas.


Headline

Gate ~ FMCU ~ management dashboard Headline.png
Nummer Funktion
1 Button Management Dashboard
2 Administration
3 Events Button
4 Cards Button
5 Statistics Button
6 Logged in User
7 Log out Button
8 Languages menu
9 Adjust the display to entire width of the screen

Gates


Set up a new Gate


Edit existing Gate


Remove Gate


Connectivity Board


Contact Type Impulse Description
A8 Output Yes (500 ms) Person has entered
A9 Output Yes (500 ms) Alarms*
E3 Input Yes (500 ms) Open Entry
E4 Input Yes (500 ms) Open Exit
E6 Input Yes (200ms) Card is valid, open the gate
E7 Input Yes (200ms) Card is invalid, do not open the gate  
E8 Input No Emergency State button**
E9 Input Yes (500 ms) Open Entry 70%
E10 Input No Fire Alarm

*A9 Alarms:

  • Gate is out of order, when a mandatory device is broken or a connection to the server is broken (if the server is used in the solution).
  • Tailgating or other unwanted actions.
  • Entry barcode scanner is broken or it is a stub.
  • Gate in in the Fire Alarm or Emergency state. The alarm is produces as a repetitive pulse signal (700ms).
  • Gate is open only for exit.

After the Emergency State button pressed, the gate switches to the Emergency State. Then only exit from this state is to restart the gate.

The signal can be set/received to/from a contact from any of the halves of the gate.

Configuration Management


User Interface

The Galaxy Gate is configured through the /configuration page. If the server is running at 192.168.1.221 and port is 8888, the url is:

http://192.168.1.221/configuration
configuration page


There are two buttons on the page:

Name Description Action
Save Saves the modified configuration to the server Post
Reset Discards any changes by reloading the configuration from the server Get

The configuration is split into sections and subsections:

  • General
    • Dispatcher
    • Miscellaneous
  • Devices
    • Barcode Reader Entry
    • Barcode Reader Exit
    • Gate
    • Tracking Camera
    • Audio Player
    • Camera
  • Displays
    • Display Gate Entry
    • Display Gate Exit
    • Display Entry
    • Display Exit
    • Display TimeInfo

Here are some screenshots:

gg-general.png
gg-barcode-reader-gate.png


gg-audio-player-camera.png


gg-tracking-camera.png
gg-displays.png


A subsection is often has a structure with a combo box named Type at the top and some fields that follow. This structure is used for configuring an entity that can have several implementations. What is important is that the implementation can differ in type and number of controls. For example, a simulator of the gate has only two properties:

gg-gate-simulator.png


Architecture

The picture below gives a bird's eye view of the configuration management.

gg-architecture-configuration-management.png


When the gate starts and the Configuration.json is present it is created from the Initial Configuration (base.py or other .py configuration file). The Schema contains a set of data for describing controls in form components:

  • Which controls should contain a component
  • Validations rules if any

E.g. a form component can contain a text box and an input for integers. The data range for integer should 1-100.

The Default Data contains the initial data for controls in form components.

Edit this section

Roadmap

The features are planned for the upcoming release:

  • Configurations page allows you to see the list of available configurations. You can:
    • Clone an existing configuration to a new one
    • Delete a configuration
    • Make a configuration active. Only one configuration can be used by the server and it is called active.
  • Apply button. This should apply changes on-the-fly.
  • Restart button. This should restart the docker container and apply settings, which cannot be applied on-the-fly.
  • Extend the vue form generator library:
    • Make the switch control consistent with the switch controls on other pages
    • Add a control which allows you to manage an array of items (e.g. the list of connected gates). E.g. https://codepen.io/safx/pen/AhCtk
  • Import/Export of a Configuration.json.
  • Reset any configuration to the default one (by removing the json file


Management of Events

The following sections contains the term Path, which means the path is part of the URL. E.g., path /events for the FMCU Server running under https://server.maxcrc.de/ means

https://server.maxcrc.de/events

Events

Web path:

/events

The page shows a filterable and sortable list of events:

Name Description
Date Date and time when the event occurred
Name Translated name of the event
Gate Gate if appropriate where the event occurred
State The state of the event if supported
Category Category to which the event belongs to
Info Additional info about the event

Edit this section

Event Definitions Page

Path:

/event-definitions

The page shows a list of definitions of events:

Name Description
Name Name
Event Definition Groups Groups to which the event belongs to if any
Supported States Can be empty (for impulse events) or On, Off (for the events with states)
Category Category to which the event belongs to

Edit this section

Event Definition Groups

Path:

/event-definition-groups

The page shows a list of event groups:

Name Description
Name Name
Events Event definitions assigned to the group
Delete Delete button

An event definition group allows you to group one or more events so that it can be bound to a user group. See Event Subscriptions below

Edit this section

Event Subscriptions

Web path:

/event-subscriptions

The page shows a list of event definition groups bound to a user groups.

Name Description
Group User group
Event definition group Event definition group
Locked When locked, events are not sent to the users of the group
Info Any informative text
Delete Delete button

When a event definition group is bound to a user group and not locked, new events from the event definition group are sent to the users from the user group. The user must have a valid email address.

Example. A user group Alarm events with two members user1 and user2 is bound to an event definition group Alarm events with two events GateTailgating and GateStateFireAlarm. When either or both of these events occur, both users user1 and user2 receive an email notification about that.

Edit this section

Configuration

Path:

/configuration

In order the emails with events can be sent out, the Email section with the information like the hostname, port etc. of the outgoing server and credentials should be properly configured.

Anhänge

Diskussionen