| | + | ==Example configuration layout with access control unit== |
| | + | Configure external device ( '''KMTronic''' [https://www.kmtronic.com/ Herstellerinformation]) |
| | + | [[Datei:image external device.png|ohne|mini]] |
| | + | |
| | + | |
| | + | The default configuration can be reviewed on the homepage of the producer. |
| | + | [[Datei:image kmtronic.png|ohne|mini]] |
| | + | |
| | + | There are a total of 4 relays for this external device, each with a normally open / normally closed contact. In the Output signals tab, you can now select a relay that will be used as a switch for access control. |
| | + | |
| | + | In this configuration, relay 1 is used as a switching contact in the signal definition. A pulse length of 0 ms is defined, which means it is an on / off switch. In this configuration, the switching pulse is set when the actual number of people is greater than the set maximum capacity. |
| | + | |
| | + | [[Datei:image relais.png|ohne|mini]] |
| | + | |
| | + | The technical connection overview is shown in this illustration. The signal lines are connected as NO (Normal Open) to contact U2 E7 on the connection board. This means that if the maximum capacity is exceeded, the access control is blocked. |
| | + | [[Datei:image network diagram.png|ohne|mini]] |
| | + | |
| | + | If necessary, several switching contacts can be used according to the technical requirements. |
| | + | |